Digital Stopwatch 0-60sec
Introduction
By
using the same circuit
of the Digital Stopwatch 0-99sec
,
we can add an AND gate,
and transform the 0 – 99sec stopwatch to a 0 – 60sec stopwatch.
We must
find a way to control the RESET function of the BCD counter,
which is responsible for the counting of the seconds. As we
studied above,
the circuit resets when we have 99 to 100, that is
1001 1001
à
0001 0000 0000. To
make a transformation successfully we must force the pulse from
59 to 60
0011 1001
à
0100 0000 on the output of the BCD counter.
By placing the AND gate,
with its inputs on the Q1
and Q2
of the BCD counter of the decades, we make sure that when the
gate closes, the RST input of the BCD counter will be set to
logical “1”, which on its turn, will force the circuit to start
over. The transformed circuit appears in picture 2. | ||||||||||||
![]() |
![]() |
|
||||||||||||
|
|
|
|
||||||||||||
|
|
||||||||||||||
|
|
||||||||||||||
|