Home
|
||||||||||||||
![]() |
![]() |
Heating System Thermostat Controlled by indoor and
outdoor temperature Simple, high reliability design
P1______________1K Linear Potentiometer
R1_____________10R 1/4W Resistor
R2______________1K 1/4W Resistor
R3______________3K3 @ 20°C n.t.c. Thermistor (see Notes)
R4______________2K2 @ 20°C n.t.c. Thermistor (see Notes)
R5_____________10K 1/2W Trimmer Cermet
R6______________3K3 1/4W Resistor
R7,R9___________4K7 1/4W Resistors
R8____________470K 1/4W Resistor
R10____________10K 1/4W Resistor
C1,C2_________470µF 25V Electrolytic Capacitors
C3______________1µF 63V Electrolytic Capacitor
D1,D2,D4_____1N4002 100V 1A Diodes
D3______________LED Red 3 or 5mm.
Q1____________BC557 45V 100mA PNP Transistor
Q2____________BC547 45V 100mA NPN Transistor
Q3____________BC337 45V 800mA NPN Transistor
RL1____________Relay with SPDT 2A @ 220V switch
Coil Voltage 12V. Coil resistance 200-300 Ohm
J1_____________Two ways output socket
SW1____________SPST Mains Switch
T1_____________220V Primary, 12 + 12V Secondary 3VA Mains transformer
PL1____________Male Mains plug & cable
Device purpose: This circuit is intended to control a heating system or central heating plan,
keeping constant indoor temperature in spite of wide range changes in the
outdoor one. Two sensors are needed: one placed outdoors, in order to sense the
external temperature; the other placed on the water-pipe returning from heating
system circuit, short before its input to the boiler. The output from the Relay
contact must be connected to the boiler's start-stop control input. Circuit operation: When Q1 Base to ground voltage is less than half voltage supply (set by R7
& R9), a voltage is generated across R8 and the driver transistors Q2 &
Q3 switch-on the Relay. When Q1 Base to ground voltage is more than half voltage
supply, caused when one of the n.t.c. Thermistors lowers its value due to an
increase in temperature, no voltage appears across R8 and the Relay is
off. Notes:
|
|
|||||||||||
![]() |
![]() |
|
||||||||||||
|
|
|
|
||||||||||||
|
|
||||||||||||||
|
|
||||||||||||||
|
Projects-Lab.com | Circuits-Lab.com | Elektrotekno.com | Free Schematics Search Engine | Electronic Kits | Mobile Phones |
||||||||||||||
|
|
||||||||||||||