Device purpose:
This circuit emits a beep and/or illuminates a LED when someone touches the
door-handle from outside. The alarm will sound until the circuit will be
switched-off. Circuit operation:
Q1 forms a free-running oscillator: its output bursts drive Q2 into
saturation, so Q3 and the LED are off. When part of a human body comes in
contact with a metal handle electrically connected to the wire hook, the body
capacitance damps Q1 oscillations, Q2 biasing falls off and the transistor
becomes non conducting. Therefore, current can flow into Q3 base and D3
illuminates. If SW1 is closed, a self-latching circuit formed by Q4 & Q5 is
triggered and the beeper BZ1 is activated. Notes:
L1 is formed winding 20 to 30 turns of 0.4mm. diameter enameled copper
wire on R2 body and soldering the coil ends to the resistor leads. You should
fill R2 body completely with coil winding: the final turn's number can vary
slightly, depending on different 1 or 2W resistor types actual length (mean
dimensions for these components are 13-18mm. length and 5-6mm. diameter).
The hook is made from non-insulated wire 1 - 2mm. diameter (brass is well
suited). Its length can vary from about 5 to 10cm. (not critical).
If the device is moved frequently to different doors, Trimmer R3 can be
substituted by a common linear potentiometer fitted with outer knob for easy
setup.
To setup the device hang-up the hook to the door-handle (with the door
closed), open SW1 and switch-on the circuit. Adjust R3 until the LED
illuminates, then turn slowly backwards the screwdriver (or the knob) until
the LED is completely off. At this point, touching the door-handle with your
hand the LED should illuminate, going off when the hand is withdrawn. Finally,
close SW1 and the beeper will sound when the door-handle will be touched
again, but won't stop until SW2 is opened.
In regular use, it is advisable to hang-up and power-on the device with
SW1 open: when all is well settled, SW1 can be closed. This precautionary
measure is necessary to avoid unwanted triggering of the beeper.
| ||||||||||||
![]() |
![]() |
|
||||||||||||
|
|
|
|
||||||||||||
|
|
||||||||||||||
|
|
||||||||||||||
|